Industrial Hardware and Specialties is classified as an ESSENTIAL business and is fully operational.

Please read our COVID-19 Message to our valued customers.

4500 Series SVR Less Bottom Rod

Hager 4500 Series SVR Less Bottom Rod

Specs

Trim: - Archer, August, William or Withnell lever with escutcheon
- Pull plate trim (excluding 45PT)
- Rim cylinder x optional pull

Covers: - Stainless steel, zinc

Cover Tube: - Aluminum

End Caps: - Zinc

Door Width: - 36'' (914 mm) field sizeable to 30'' (762 mm) panic-rated door and 28" (711 mm) fire-rated door
- 48'' (1219 mm) field sizeable to 36'' (914 mm) panic- or fire-rated door
- Reference electrified exit device for door width specifications

Door Height: - 7' (2134 mm) - Standard
- 8' (2438 mm) - Optional
- 10' (3048 mm) - Optional (panic device only)

Door Thickness: - 1-3/4" (44 mm) - Standard up to 3", except with night latch which is 2-1/2"

Stile Width: - 5-3/8" (137 mm) minimum stile width required for single door and 5/8" (16 mm) stop
- 4-7/8" (124 mm) minimum stile width required for double doors
- 4-7/8" (124 mm) minimum stile width required for double door x Rim device with double door strike
- All stile widths are measured from door edge

Fasteners: - Wood and machine screws
- Thru-bolts

Rod Length: - Rods for 7' (2134 mm) door - Standard
- Rods for 8' (2438 mm) door - Optional
- Door height of 7' (2134 mm) requires 33-1/4" (845 mm) top rod length
- Door height of 8' (2438 mm) requires 45-1/4" (1149 mm) top rod length
- Extension rod kits available, 2' (610 mm) or 3' (914 mm) for doors over 7' (2134 mm)

Latchbolt: - Top- 1/2" (13 mm) throw- pullman type with automatic dead latching, stainless steel

Strikes: - Stainless steel with plated rollers - Included standard with panic devices
- Solid stainless steel - Included standard with fire rated devices
- Surface applied to frame with slotted holes for easy adjustment
- Double door strike for use with surface vertical rod and rim device available

 Finishes:
- US3, US4, US10, US10B, US 26, US26D, US32D
- Trim is not available in US32D

 Dogging:
- Hex key dogging standard on panic rated devices
- Cylinder dogging is available on panic-rated devices, specify "CD" (3902 1-1/8" (29 mm) mortise cylinder sold separately)

 Projection:
- 3" (76 mm) in undogged position
- 2-5/8" (67 mm) in dogged position

 Notes:
- Hole plug for head cover included standard
- Recommended to be used on appropriately reinforced doors
- A spring loaded fire bolt 2-649-0166 must be used on fire-rated LBR devices used on a pair of doors to ensure the device's fire rating.

Templates

Description File Number
45ET Electrical Supplemental Instructions I-ED00370
4500 Series with Rim Cylinder Template T-ED00862-Template
4500 SVR Door Prep Template T-ED00873-Template
4500 SVR Latch Template T-ED00045-Template
4500 SVR Chassis Template T-ED00044-Template

Installation

Description File Number
Auxiliary Fire Latch Installation Instructions I-ED00863-Installation
4500 SVR Installation Instructions I-ED00792

Related Files

Description File Number
Exit Lever Options Exit Lever Options
UL Listed Fire Rated Exit Hardware UL Listed Fire Rated Exit Hardware
4500 SVR LBR Full Image 4500_LBR_large-Related File
Categories: Exit Devices